A.4 Pump<br />
The pump of a <strong>binder</strong> <strong>distributor</strong> is a positive displacement gear<br />
pump which means that the quantity of <strong>binder</strong> that is delivered is<br />
directly proportional to the speed of the pump. The pump is normally<br />
driven by means of an independent engine, but some newer models<br />
are driven by the power take off (PTO) from the gearbox of the<br />
vehicle. On some <strong>distributor</strong>s pressure is governed by variable pump<br />
speed and on others by constant pump speed and a pressure relief<br />
valve.<br />
When a pressure relief valve is used, the pump runs at a constant<br />
speed and the pressure is automatically maintained in the spray-bar.<br />
The manufacturer supplies charts <strong>for</strong> determining the discharge in<br />
litre per minute <strong>for</strong> each size nozzle as well as the required truck<br />
speeds <strong>for</strong> various application rates and the corrections <strong>for</strong><br />
temperature-viscosity variations.<br />
Figure 8: Pump mounted on the back of the <strong>distributor</strong><br />
15