A.5 Pipework<br />
All pipes and couplings which are part of the <strong>distributor</strong> circuit shall<br />
be able to handle the maximum pressure and temperature required.<br />
A.6 Strainers<br />
Provision is made <strong>for</strong> filtering bituminous materials. Every vehicle<br />
should be fitted with a loading strainer and a spraying strainer. On<br />
the loading side this can be achieved either by an external strainer<br />
which should be available with the <strong>distributor</strong> at all times, or by an<br />
in-line removable strainer in the suction pipe. An additional<br />
removable strainer should be fitted on the discharge side of the<br />
pump. Strainers should be checked and cleaned regularly and spare<br />
strainers should be readily available on the <strong>distributor</strong>.<br />
Figure 9: Strainer<br />
16