APPENDIX E<br />

Check list be<strong>for</strong>e spraying commences on site<br />

Distributor Identification Number<br />

No. Item Yes No<br />

1.1 Does the <strong>distributor</strong> have a valid Calibration<br />

Certificate<br />

• Was the calibration issued by a SANAS<br />

accredited facility<br />

• Is the certificate within its validity period<br />

• Does the certificate specify which<br />

components of the <strong>distributor</strong> have been<br />

calibrated and is there proof of calibration<br />

from an accredited facility that other<br />

components have also been calibrated and<br />

are their certificates valid<br />

1.2 Check the Modification and maintenance log:<br />

are all modifications acceptable and recorded<br />

and have these modifications been re-calibrated<br />

(If deemed necessary) and is there proof of it in<br />

the logbook.<br />

1.3 Check if all the relevant equipment mentioned in<br />

the above two items correspond (In terms of<br />

identification) to the respective certificates of<br />

calibration.<br />

1.4 Inspect the 'Bucket' Test record.<br />

1.5 Inspect the Per<strong>for</strong>mance log.<br />

1.6 Has the <strong>distributor</strong> inspection check been carried<br />

out successfully (see Appendix A).<br />

1.7 After inspection of the 'Bucket Test' record and<br />

the Per<strong>for</strong>mance log; does the client or his agent<br />

require that a 'Bucket Test' be done<br />

... continued overleaf<br />

43