Manual 31 Guidelines for calibrating a binder distributor ... - Aapaq.org
Manual 31 Guidelines for calibrating a binder distributor ... - Aapaq.org
Manual 31 Guidelines for calibrating a binder distributor ... - Aapaq.org
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
PART B: DETAILS OF THE INSPECTION AND<br />
TEST PROCEDURES TO BE CARRIED OUT<br />
TO OBTAIN A CALIBRATION CERTIFICATE<br />
FOR A BINDER DISTRIBUTOR IN<br />
ACCORDANCE WITH SANS 3001-BT20<br />
The purpose of the calibration procedure and certificate is to provide<br />
an annual check of bitumen <strong>distributor</strong>s to ensure that they are in a<br />
reasonable condition, that the tank is clean and that there is a high<br />
probability of achieving the desired result on site.<br />
A credible and valid Calibration Certificate will give the assurance<br />
that the <strong>binder</strong> <strong>distributor</strong> is operating correctly and that it is capable<br />
of delivering the required application rate within the prescribed<br />
tolerances. It is, however, not a guarantee of accurate and uni<strong>for</strong>m<br />
spraying capability. In addition to the annual Calibration Certificate<br />
and depending on the nature and size of the project a number of<br />
tests and inspections may be carried out on site prior to and during<br />
spraying operations to ensure the required quality of spray work.<br />
It is recommended that the calibration tests are carried out in the<br />
order that they are listed below. This will ensure best time and<br />
resource efficiency and will prevent repetition of some steps.<br />
The Calibration Certificate as well as the calibration parameters,<br />
such as road speed and pump output, are to be made available <strong>for</strong><br />
inspection on site to assess the extent to which site tests need to be<br />
carried out and on-site per<strong>for</strong>mance monitored to ensure compliance<br />
with the specification. The data should be kept on board the<br />
<strong>distributor</strong>.<br />
B.1 Required annual tests<br />
The following tests specified in SANS 3001-BT20 are required <strong>for</strong><br />
annual certification of a <strong>binder</strong> <strong>distributor</strong>:<br />
• SANS 3001 BT-21Validation of a <strong>binder</strong> <strong>distributor</strong> dipstick;<br />
20