Performance charts.<br />

daPa<br />

80<br />

60<br />

40<br />

20<br />

0<br />

C.75 GX 507 p20/25<br />

mbar<br />

0<br />

100 300 500 700 900 1100 kW<br />

140 335 750<br />

C.75 GX 507/8 p37-148-300<br />

daPa<br />

mbar<br />

8<br />

6<br />

4<br />

2<br />

daPa<br />

80<br />

60<br />

40<br />

20<br />

0<br />

C.100 GX 507 p20/25<br />

mbar<br />

0<br />

100 300 500 700 900 1100 kW<br />

170 520 1040<br />

C.100 GX 507/8 p37-148-300<br />

daPa<br />

mbar<br />

8<br />

6<br />

4<br />

2<br />

Packing.<br />

The burner is delivered in three<br />

separately packaged palettes weighing<br />

between 74 and 79kg depending on<br />

the model.<br />

• Burner body:<br />

- Integrated electrical bearing plate,<br />

- Boiler plate,<br />

- Documentation, including:<br />

- operating instructions,<br />

- electrical and hydraulic<br />

diagrams,<br />

- certificate of guarantee.<br />

• Combustion head:<br />

- front boiler attachment, a set of<br />

fasteners.<br />

• Gas rack:<br />

- valve set and collector.<br />

80<br />

8<br />

80<br />

8<br />

60<br />

6<br />

60<br />

6<br />

40<br />

4<br />

40<br />

4<br />

Front panel boring.<br />

20<br />

2<br />

20<br />

2<br />

0<br />

0<br />

100 300 500 700 900 1100 kW<br />

140 335 750<br />

Output levels.<br />

0<br />

0<br />

100 300 500 700 900 1100 kW<br />

170 530 1040<br />

Ø 260max<br />

Ø 195<br />

C.75 49 AQ 0924 C.100 49 AQ 0925<br />

20/25 37/148 300 20/25 37/148 300<br />

Output KW mbar mbar mbar mbar mbar mbar<br />

min max min max min max min max<br />

Burner (kW) 335 680 750 750 530 720 1040 1040<br />

Min. 1 st startup (kW) 140 — — — 170 — — —<br />

Boiler (kW) 310 625 690 690 490 665 960 960<br />

In bold, recommended ø.<br />

Bulk and dimensions.<br />

valve<br />

A minimum of 0.80m must be allowed<br />

on either side of the burner for<br />

maintenance purposes.<br />

Ventilation in the boiler room.<br />

1.2m 3 of new air is required for every<br />

kWh produced by the burner.<br />

Gas rack.<br />

The rack can only be installed<br />

horizontally, to the right or left.<br />

Note:<br />

The burner may be installed with the<br />

casing at the top or bottom.