8.10. Securing for uplift<br />
Products must be fixed as soon as they are placed on the roof or façade to<br />
avoid any uplift due to the action of the wind.<br />
Before interrupting the work, it is necessary to check that all the products are<br />
properly fixed and the bundles are also fixed with some straps to avoid risks of<br />
falling materials.<br />
Direction of installation is important for an easier secure.<br />
8.11. Holes<br />
Pipe penetrations must be properly made in concordance with the design taking<br />
in consideration that:<br />
• Pipes can not transmit forces to the façade<br />
• Reduction of the thermal bridges is a must<br />
• Flashings must be water and air tight<br />
8.12. Design of flashings<br />
Flashings must be defined following some recommendations:<br />
• Flat surface shouldn’t be larger than 250 mm to keep the flatness<br />
• Small slope is recommended to avoid water retention.<br />
• Drip is recommended in any flashing to reduce the dirty on the façade.<br />
ArcelorMittal Construction Page 13 of 21<br />