6. Cutting and drilling during installation<br />
6.1. Cutting<br />
Panels can not be cut with abrasive tools.<br />
Most kinds of saws are suitable to cut steel<br />
sheets and panels if they don’t burn the<br />
material as abrasive tools.<br />
Metal shavings have to be removed from the<br />
area to avoid adverse optical and warranty<br />
issues.<br />
During the cuts, the area where the saw tool<br />
can scratch the sheet must be protected.<br />
6.2. Drilling<br />
Metal shavings from these operations have to be removed to avoid optical and<br />
warranty issues.<br />
7. Anchoring, fixing and connecting the panels during<br />
installation<br />
7.1. General<br />
Depending on the final use of the sheet / panel, its dimension and the<br />
supporting structure, several fixings systems can be used.<br />
Fasteners must have an appropriate corrosion protection for the environment<br />
where the buildings are located.<br />
<strong>Installation</strong> and dimension of the fasteners is described in the next points<br />
7.2. Fixations and how to fix<br />
The next points will describe the possible fasteners, how they must be fitted and<br />
the field of application.<br />
ArcelorMittal Construction Page 7 of 21<br />