Parameter (5,000 kg insulin /<br />

year)<br />

Batch Xie (2002) Overall Optimized SMB<br />

Overall Yield (%) 89 99 99<br />

Column<br />

Configuration<br />

Ring A<br />

2-2-4-2 2-2-4-2<br />

12 in series<br />

Ring B 2-3-3-2 2-2-2-2<br />

Feed Flowrate (mL/min) 11 (each) 115 115<br />

Column Length (cm)<br />

Diameter (cm)<br />

Ring A<br />

13.7 9.34<br />

15<br />

Ring B 13.7 7.02<br />

Ring A 45<br />

47.9 27.2<br />

Ring B (12 units) 58.6 42.6<br />

Throughput (L/h/100 L BV) .23 1.19 5.36<br />

Solv. consumption (L/kg insulin) 150 42 55.6<br />

Equip. Cost ($/kg insulin) 35.71 29.76 29.17<br />

Solv. Cost ($/kg insulin) 15 4.20 5.56<br />

Resin Cost ($/kg insulin) 40.07 7.41 1.61<br />

Total Cost ($/kg) 90.78 41.50 36.35