28.01.2015 Views

Hermetic Compressor - Tecumseh

Hermetic Compressor - Tecumseh

Hermetic Compressor - Tecumseh

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

53<br />

This CSIR compressor has the following components:<br />

Thermal Protector Type Relay Type Capacitor Type<br />

Internal External Current Potential PTC Run Start<br />

√ √ √<br />

The electrical system on this type of motor is shown in FIGURE 4-6. The actual position of<br />

terminals on the relay may be different than shown in FIGURE 4-6. Use the letters and/ or<br />

numbers on the actual relay to locate the terminals.<br />

If replacement parts are needed, refer to the <strong>Tecumseh</strong> Electrical Service Parts Guide<br />

Book for information on proper replacement parts, or call <strong>Tecumseh</strong> Products Company at<br />

1-800-211-3427.<br />

External Thermal Protector<br />

Line 1<br />

Control<br />

C<br />

Line 2<br />

Ground<br />

Fan*<br />

5 2<br />

Relay - Potential<br />

S<br />

Start Winding<br />

Main Winding<br />

<strong>Compressor</strong> - Unit<br />

Ground<br />

4<br />

6<br />

1<br />

R<br />

Start Capacitor<br />

Bleeder Resistor<br />

Note: #4 and #6<br />

on relay are<br />

dummy terminals<br />

*Other auxiliary devices may be attached. Disconnect any auxilliary devices in Step 2.<br />

FIGURE 4-6: CSIR compressor motor type with external thermal<br />

protector, potential relay mounted remote and start capacitor.