AC and DC Side Panels<br />

The DC side of the <strong>Freedom</strong> <strong>SW</strong> <strong>3000</strong> has the equipment ground lug, the<br />

positive (+) battery terminal, and the negative (–) battery terminal plus the<br />

remote network com port and battery temperature sensor com port.<br />

1<br />

REM<br />

2<br />

BTS<br />

Figure 5 AC and DC Side Panel<br />

3<br />

WARNING: INCORRECT BATTERY POLARITY WILL CAUSE DAMAGE TO UNIT.<br />

4 9 8<br />

INVERTER<br />

AC OUTPUT<br />

Wiring box cover must be in place during<br />

use to reduce risk of injury to persons<br />

7 6<br />

AC INPUT<br />

LINE 1<br />

AC INPUT<br />

LINE 2<br />

5<br />

AC<br />

IN<br />

AC<br />

OUT<br />

AC GROUNDS<br />

(BEHIND COVER)<br />

<strong>Freedom</strong> <strong>SW</strong> <strong>3000</strong> <strong>Inverter</strong>/<strong>Charger</strong> Features<br />

975-0545-01-01 9<br />

Item<br />

Description<br />

1 Remote (REM) jack provides connection for the<br />

<strong>Freedom</strong> <strong>Sine</strong> <strong>Wave</strong> remote panel (supplied).<br />

2 Battery temperature sensor (BTS) jack provides<br />

connection for the battery temperature sensor (supplied).<br />

3 Negative (–) DC terminal connects to the negative<br />

battery cable (black). Install a DC terminal cover<br />

(supplied) over the terminal.<br />

4 Positive (+) DC terminal connects to the positive battery<br />

cable (red). Install a DC terminal cover (supplied) over<br />

the terminal.<br />

5 AC Input 1, AC Input 2, and <strong>Inverter</strong> AC Output<br />

circuit breaker switches allow you to reset the circuit<br />

breakers when they trip.<br />

6 AC knockouts provide access for AC cables (both input<br />

and output wiring). Detach the knockout covers and<br />

install the strain-relief clamps (supplied).<br />

7 AC Output terminal block is a screw-type terminal<br />

block for attaching AC output wires. Each slot is labeled<br />

N1 for Neutral 1, L1 and L2 for Lines 1 and 2, and N2 for<br />

Neutral 2.<br />

8 AC Input terminal block is a screw-type terminal block<br />

for attaching AC input wires. Each slot is labeled<br />

N for Neutral and L1 and L2 for Lines 1 and 2.<br />

9 Chassis ground lug connects the chassis of the F<strong>SW</strong><strong>3000</strong><br />

to your system’s chassis grounding point.<br />

Not<br />

shown<br />

All Ground terminals are along the tab at the bottom of<br />

the opening to the AC wiring compartment access panel.