1. SCREEN INDICATIONS AND OPERATIONS B–<strong>63325EN</strong>/<strong>03</strong><br />

Cause for not starting<br />

1005<br />

#7<br />

#6 #5 #4 #3 #2<br />

OTH<br />

#1<br />

RPO<br />

#0<br />

JMD<br />

Bit Name Internal state when “1” is indicated<br />

#0 JMD DI and DO signals are incorrect in a manual<br />

numeric command (*1).<br />

#1 RPO DI and DO signals are incorrect in repositioning<br />

for tool retraction and recovery (*2).<br />

#2 OTH Others (*3).<br />

1006<br />

#7<br />

RVS<br />

#6<br />

PTR<br />

#5<br />

MDI<br />

#4<br />

NOP<br />

#3<br />

EDT<br />

#2<br />

SRN<br />

#1<br />

ALM<br />

#0<br />

*SP<br />

Bit Name Internal state when “1” is indicated<br />

#0 *SP The automatic–operation stop signal (*SP) is “0.”<br />

#1 ALM An alarm is generated.<br />

#2 SRN The SRN signal or the BRN signal is “1.”<br />

#3 EDT An attempt was made to execute a program being<br />

background edited.<br />

#4 NOP The device is not ready in the DNC mode.<br />

#5 MDI The contents which the MDI executed is<br />

remaining.<br />

#6 PTR The tool retraction signal (TRESC) is “1.”<br />

Alternatively, the tool is not returned to the<br />

position where the tool retraction signal was input.<br />

#7 RVS Reverse operation of the program cannot be<br />

performed.<br />

If a bit becomes “1,” remove the cause and then restart.<br />

Multiple bits cannot become “1.” Even if multiple causes happen, the bit<br />

corresponding to the last cause becomes “1.”<br />

NOTE<br />

1 The DEN signal or the IPEN signal of DO is “1.”<br />

Constant surface speed control is being executed.<br />

The state of HEAD1/2 of DI is wrong in the MDI mode (only<br />

for TT series).<br />

2 The OP signal of DO is “0” in a repositioning operation of tool<br />

retraction and recovery.<br />

The MLK signal of DI is “1.”<br />

The STL signal of DO is “1.”<br />

3 A retraction operation is being performed in the hobbing<br />

machine.<br />

In the bed grinding machine, an alarm is being generated<br />

or the MLK signal of DI is “1.”<br />

The axis to be jog retracted is at a position where movement<br />

cannot be started.<br />