Page 6 of 8<strong>ICAF</strong> - Integrated Compressed Air Foam <strong>System</strong>Controls Section<strong>System</strong> Output Activation:- an ALARM contact for the ALARM transmission to theMain Fire Alarm Building panel will be activated.- an ALARM signalling circuit will be activated.- The <strong>release</strong> circuit will be activated and the CAFdischarge will occur.- The DISCHARGE contact will be activated for auxiliaryfunction.The activation of mechanical emergency manual stationinside the <strong>ICAF</strong> cabinet will cause the following:On the Control Panel Annunciator:- the zone in alarm (WATERFLOW) will be displayed.- the ALARM LED will flash- the local buzzer will sound.- the Discharge LED will illuminate<strong>System</strong> Output Activation:- an ALARM contact for the ALARM transmission to theMain Fire Alarm Building panel will be activated.- an ALARM signalling circuit will be activated.- the CAF discharge will occur and the DISCHARGEcontact will be activated for auxiliary function.Automatic DischargeNote: BEFORE CLOSING A VALVE OR ACTIVATING ANALARM, ADVISE THE SECURITY GUARD AND THECENTRAL SUPERVISORY STATION. THIS IS TOAVOID DISPATCHING THE FIRE DEPARTMENT INCASE OF A FALSE ALARM.Inspection LogThe function key F1 labelled "Inspection Log" is used inconjunction <strong>with</strong> the ARC-1 Remote Interface software forPC.The CAF discharge will occur for 10 minutes. At the end ofthe soak timer, the CAF discharge will automatically stop.The Release LED will then start flashing.Emergency discharge Shut-OffBecause the <strong>ICAF</strong> <strong>System</strong> cannot be turned off by theoperation of a single valve as is the case for a standardsprinkler system, a manual shut-off function is provided. TheCAF discharge can be manually suspended using thefollowing sequence of operation:1. Press and hold the function key F3 labelled: "<strong>System</strong>Shut-Off" on the keypad of the ARC-1 panel until itsadjacent red lamp is turned On.2. Close the system main water supply valve inside the<strong>ICAF</strong> cabinet. The red lamp labelled "Dischargesuspended" will turn On.Note: Mechanical emergency <strong>release</strong> valve must be innormal position prior the CAF discharge shut-off.IMPORTANT: After a fire, make sure it is completelyextinguished. If necessary, place a fire patrol in thezone covered by the system. Foam systems that havebeen subjected to fire must be returned to service assoon as possible. The entire system must be inspectedfor damage, and repaired or replaced as necessary.Warning! DO NOT CLOSE THE WATER SUPPLY TOMAKE REPAIRS WITHOUT PLACING A FIRE PATROLIN THE AREA COVERED BY THE SYSTEM. THEPATROL SHALL REMAIN THERE UNTIL THE SYSTEMIS BACK IN OPERATION. Advise local authorities of thenecessary work over the fire protection equipment.Follow emergency procedures required by codes and theAuthority Having Jurisdiction during system maintenance.FM-0723-0-17 B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!