10.07.2015 Views

ICAF System with electric Failsafe release - FIREFLEX SYSTEMS

ICAF System with electric Failsafe release - FIREFLEX SYSTEMS

ICAF System with electric Failsafe release - FIREFLEX SYSTEMS

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Page 2 of 10<strong>ICAF</strong> - Integrated Compressed Air Foam <strong>System</strong>General Section- Very dependable stainless steel pressure vessel typefoam tank, <strong>with</strong>out bladder- Air supply cylinders bank factory assembled and tested- User-friendly standardized owner's manual <strong>with</strong> everyunit- Unique serial number on every mixing chamber- Trim fully assembled and tested at the factory- Grooved end water supply and drain connections onboth sides of the cabinet- Sturdy 14 Gauge steel cabinet painted fire red <strong>with</strong> ovenbaked polyester powder on phosphate base (powdercoated)- Textured rust proof finish- Neoprene gasket on all doors to eliminate vibrations- Easily removable doors for ease of access- Key-alike locks on all cabinet doors- Manufactured under ISO-9001 quality controlprocedures.Configuration DescriptionAn <strong>ICAF</strong> <strong>System</strong> is a fixed deluge-type fire suppressionsystem which totally floods an area or hazard <strong>with</strong>compressed air foam through a piping system of opennozzles. The system piping is empty until the system isactivated by a pneumatic, <strong>electric</strong> or manual <strong>release</strong> system.Single zone configuration can be used to protect smallerhazards whereas multiple zones and multiple mixingchambers configurations can be used to protect largerhazards or a combination of smaller independent hazards.<strong>System</strong> requires a reliable and automatic water supply. Airsupply is provided by compressed air cylinders mounted on askid and includes an air pressure regulator. Foamconcentrate is contained inside a stainless steel tank. Uponsystem activation, the foam concentrate tank is pressurizedand water, air and foam concentrate are injected and mixedtogether inside a mixing chamber. Compressed Air Foam isthen generated and moves inside the piping network towardthe distribution nozzles.<strong>ICAF</strong> <strong>System</strong>s trims including water, air and foam controls,CAF mixing chamber and <strong>release</strong> system are factoryassembled in cabinets and available in self-contained,remote controlled and extension unit configurations to suitproject's requirements. A description of the available unitsfollows: Self-Contained UnitThis unit includes all the mechanical controls & trims,CAF mixing chamber(s) and is provided <strong>with</strong> the ARC-1releasing control panel.Components size and quantity of mixing chambers aredetermined by the system's flow and configurationrequired to supply the nozzles in the hazard(s). Remote Controlled UnitThis unit is used when an additional zone is required tobe protected by the same system. This unit includes allthe mechanical controls, trims and CAF mixingchamber(s) and is provided <strong>with</strong> a field wiring junction boxin lieu of the releasing control panel enclosure. Thisshould then be connected to the control panel of the selfcontainedunit.Components size and quantity of mixing chambers aredetermined by the system's flow and configurationrequired to supply the nozzles in the hazards. Extension UnitThis unit is used when additional mixing chambers arerequired to supply a single zone <strong>with</strong> a larger amount ofnozzles. This unit includes the CAF mixing chamber(s)<strong>with</strong>out any controls or releasing control panel. It shouldbe used in parallel <strong>with</strong> a self-contained unit or a remotecontrolled unit.Water SupplyCAF technology offers an important reduction in the watersupply requirements compared to standard sprinklers orfoam systems. The system can operate <strong>with</strong> a waterpressure in the range of 50 to 175 psi (345 to 1206 kPa).The <strong>ICAF</strong> <strong>System</strong> is dependable, automatic and capable ofproviding the required flow and pressure for the requiredduration.<strong>ICAF</strong> <strong>System</strong> uses pneumatically actuated globe valves for¾" (20 mm) diameter or Listed fire protection flow controlvalves for 1½" (40 mm) diameters and up.All the valves are rated up to a maximum of 175 psi WWP(1206 kPa) and are available in the following diameters: ¾" (20 mm) 1½" (40 mm) 2" (50 mm) 3" (80 mm)When water pumps are required for system operation, theyshall be designed and installed in accordance <strong>with</strong> NFPA 20,Standard for the Installation of Centrifugal Fire Pumps.The water system shall be designed and installed inaccordance <strong>with</strong> NFPA 24, Standard for the Installation ofPrivate Fire Service Mains and their Appurtenances. Astrainer shall be provided on water supplies containing solidslikely to clog orifices. Such strainers shall be provided <strong>with</strong> acleanout port and shall be arranged to facilitate inspection,maintenance and replacement.Air SupplyCAF is 90% compressed air. Air is provided by cylindersbank as described in the Air Supply Section.The connection is used to supply compressed air betweenthe cylinders bank and the <strong>ICAF</strong> <strong>System</strong>. The piping isfactory prepared according to installation arrangement and issupplied <strong>with</strong> the system. The system can be configured for: Single air interconnection line (circled item 4). Multiple air interconnection lines (circled item 4).FM-0723-0-07 C

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!