10.07.2015 Views

domus - the complete solution - CMS

domus - the complete solution - CMS

domus - the complete solution - CMS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

EASIPIPEup to 400 m 3 /hrEASIPIPE 100Product Code Description Dimensions Pressure loss.pa Notes i.d. = internal dimensionBoxed Prepack mm 15 l/s 30 l/s 60 l/s o.d. = outer dimension135-4 40135 Standard Round Pipe, 350mm1100-4 41100 Standard Round Pipe, 1m1200-4 n/a Standard Round Pipe, 2m● 100 0.17 0.5 1.1● 100 0.5 1.4 3.1● 100 1 2.8 6.2Fits over components with 100mmo.d. round spigots e.g. 490, 491,492, 493/4/5, wall outlets andcooker hoods.2100-4 n/a Round Pipe Outer Sleeve, 1mO 104 0.5 1.4 3.1Fits over standard round pipe tocreate a telescopic assembly.130-4 n/a Telescopic Assembly, 250-450mmInner pipe● 100Outer pipeO 104Figures vary accordingto length requiredAdjustable between 250-450mm.Includes reducing ring so that bo<strong>the</strong>nds have 100mm i.d. to fit overcomponents with 100mm o.d.Recommended for ducting throughcavity walls.380 n/a Adapter to Round SocketO 100 - - -Fits into 100mm i.d. round pipe tomake connections to sockets with100mm i.d.490 40490 90° BendO 100 5.6 21.1 80.1Fits into 100mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r at90°.491 40491 45° BendO 100 2.1 8.2 31.4Fits into 100mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r at45°.492 40492 Equal T-Piece499M n/a Equal Y-Piece, metal (not shown)O 100O 100Figures vary on installationFigures vary on installationFits into 100mm i.d. round pipe toprovide a round ducting junction ina multi-extraction installation.493 40493 Straight Pipe ConnectorO 100 0.9 4.2 20.4Fits into 100mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r in astraight line.494 40494 Straight Pipe Connectorwith DamperO 100 25 44.9 101.6Fits into 100mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r in astraight line. Includes damper forback draft prevention.495 n/a Straight Pipe Connectorwith Damper and Wall Plate496 40496** Pipe FastenerO 100 25 44.9 101.6- - - -Fits into 100mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r in astraight line. Includes damper forback draft prevention and integralwall plate.Fastens over Easipipe 100 tosecure pipe to <strong>the</strong> wall, ceiling orjoists in a horizontal or verticalposition.26● = internal dimensionO = outer dimensionPlease refer to pages 9-13 forWall Outlets for this range

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!