10.07.2015 Views

domus - the complete solution - CMS

domus - the complete solution - CMS

domus - the complete solution - CMS

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EASIPIPEEASIPIPE 125 CONT.Product Code Description Dimensions Pressure loss.pa Notes i.d. = internal dimensionBoxed Prepack mm 15 l/s 30 l/s 60 l/s o.d. = outer dimension592 n/a Equal T-Piece599M n/a Equal Y-Piece, metal (not shown)O 125O 125Figures vary on installationFigures vary on installationFits into 125mm i.d. round pipe toprovide a round ducting junction ina multi-extraction installation.593 n/a Straight Pipe ConnectorO 125 0.2 0.9 4.3Fits into 125mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r in astraight line.594 n/a Straight Pipe Connectorwith DamperO 125 18.3 31.5 61.7Fits into 125mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r in astraight line. Includes damper forback draft prevention.595 n/a Straight Pipe Connectorwith Damper and Wall PlateO 125 18.3 31.5 61.7Fits into 125mm i.d. round pipe toconnect two lengths toge<strong>the</strong>r in astraight line. Includes damper forback draft prevention and integralwall plate.596 n/a Pipe Fastener- - - -Fastens over Easipipe 125 tosecure pipe to <strong>the</strong> wall, ceiling orjoists in a horizontal or verticalposition.114-5 n/a Round Wall Plate● 128 - - -170 x 170Fits over 125mm i.d. round pipe orflexible hose to make good internalwall after drilling of hole.119 40119 Circular Adapter 125-100mmO 100 1.5 5.9 24● 125Fits into 100mm i.d. connectionsand over 125mm o.d. spigots toadapt between two sizes in astraight line.118 n/a Circular Adapter 150-125mmO 125 0.6 2.2 8.8● 150Fits into 125mm i.d. connectionsand over 150mm o.d. spigots toadapt between two sizes in astraight line.519 n/a Rubber Spigot Adapter120-125mm- - - -Adapts 115 - 122mm o.d.spigots to 125mm roundducting connections. Ideal forcooker hoods.● = internal dimensionO = outer dimensionPlease refer to pages 9-13 forWall Outlets for this rangeThe <strong>solution</strong> to create an effective, simple and airtight fit whenconnecting 115 - 122mm spigots to 125mm ducting systems.28Many cooker hoods have spigots between 115 - 122mm and, to ensureefficient airflow performance, <strong>the</strong>y must use 125mm ducting. The ‘519’enables this to be done without <strong>the</strong> use of excessive padding, taping orjust having a loose fit, which causes air leakage.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!