M1ALG3– Single DeckApplication:11CASE DATA 04 06 08 12Anti-Sweat Amps .35 .47 .59 .82Fan Amps .37 .37 .37 .74Light Amps N/A N/A N/A N/ADefrost Load Amps (If elec-230V) 3.30 5.61 7.93 11.54# Defrosts Required 3 3 3 3Evaporator Temperature °F +15° +15° +15° +15°BTU Requirements 1980 2970 3960 5940NOTE: For sizing conventional/individual condensing units ADD 8% to BTU LOAD.Defrost Per Day Fail Safe TerminationOff Cycle 3 40 min 55°Hot gas 3 18 min 55°Electric 3 30 min 55°Discharge Air Velocity225 - 250 FPMDischarge Air Temp 22 - 26°FType I refrigerator, intended for use in an area where the environmental conditionsare controlled and maintained such that conditions do not exceed 75 deg Fand 55% relative humidity. <strong>Kysor</strong>//<strong>Warren</strong>, whose policy is one of continuousimprovement, reserves the right to change at any time, specifications, design orprices without incurring obligation.Dual-Jet and Air Defrost are registered trademarks of <strong>Kysor</strong>//<strong>Warren</strong>.The above case model, has case lengths thatare UL and NSF approved.Issue: Sept - 06