QD63– Multi-DeckApplication:25CASE DATA 04 06 08 12Anti-Sweat Amps NA NA NA NAFan Amps 0.52 0.70 1.04 1.56Light Amps (Two rows canopy) 0.46 0.92 0.92 1.48Defrost Load Amps None None None None# Defrosts Required 4 4 4 4Evaporator Temperature °F +23° +23° +23° +23°BTU Requirements 5200 7800 10400 15600NOTE: For sizing conventional/individual condensing units ADD 8% to BTU LOAD.All electrical data based on 115V and unlighted shelves. For lighted shelves, pleaseadd 98 BTU and .25 amps per shelf. Add 0.063 amps per foot for nose light.Defrost Per Day Fail Safe TerminationOff Cycle 4 30 min 48°Hot gas 4 20 Min 48°Discharge Air VelocityDischarge Air Temp275 FPM31.5°FType I refrigerator, intended for use in an area where the environmental conditionsare controlled and maintained such that conditions do not exceed 75 deg Fand 55% relative humidity. <strong>Kysor</strong>//<strong>Warren</strong>, whose policy is one of continuousimprovement, reserves the right to change at any time, specifications, design orprices without incurring obligation.Dual-Jet and Air Defrost are registered trademarks of <strong>Kysor</strong>//<strong>Warren</strong>.The above case model, has case lengths thatare UL and NSF approved.Issue: Sept - 06