D73– 88” TallApplication:27CASE DATA 06 08 12Anti-Sweat Amps N/A N/A N/AFan Amps 1.06 1.06 1.59Light Amps (Two rows canopy) 0.90 .92 1.48Defrost Load Amps None None None# Defrosts Required 4 4 4Evaporator Temperature °F +20° +20° +20°BTU RequirementsNOTE: For sizing conventional/individual condensing units ADD 8% to BTU LOAD.All electrical data based on 115V and unlighted shelves. For lightedshelves, please add 98 BTU and .25 amps per shelf. Add 0.063 ampsper foot for nose light.Defrost Per Day Fail Safe TerminationOff Cycle 4 40 min 55°Hot gas 4 20 min 55°Discharge Air Velocity275 - 375 FPMDischarge Air Temp 28 - 32°FType I refrigerator, intended for use in an area where the environmental conditionsare controlled and maintained such that conditions do not exceed 75 deg Fand 55% relative humidity. <strong>Kysor</strong>//<strong>Warren</strong>, whose policy is one of continuousimprovement, reserves the right to change at any time, specifications, design orprices without incurring obligation.Dual-Jet and Air Defrost are registered trademarks of <strong>Kysor</strong>//<strong>Warren</strong>.Issue: Sept - 06