QM5G3 – Multi-DeckApplication:42CASE DATA 04 06 08 12Anti-Sweat Amps N/A N/A N/A N/AFan Amps (SP) .52 .70 1.04 1.56Light Amps (Two rows canopy) .50 .80 1.00 1.50Defrost Load Amps (If elec-230V) 3.30 5.61 7.93 11.54# Defrosts Required 3 3 3 3Evaporator Temperature °F +23° +23° +23° +23°BTU Requirements 5580 8370 11160 16740NOTE: For sizing conventional/individual condensing units ADD 8% to BTU LOAD.All electrical data based on 115V and unlighted shelves. For lightedshelves, please add 98 BTU and .25 amps per shelf.Defrost Per Day Fail Safe TerminationOff Cycle 3 35 min 48°Hot gas 3 20 min 48°Electric 3 35 min 48°Discharge Air Velocity 225 FPMDischarge Air Temp 29°FType I refrigerator, intended for use in an area where the environmental conditionsare controlled and maintained such that conditions do not exceed 75 deg Fand 55% relative humidity. <strong>Kysor</strong>//<strong>Warren</strong>, whose policy is one of continuousimprovement, reserves the right to change at any time, specifications, design orprices without incurring obligation.Dual-Jet and Air Defrost are registered trademarks of <strong>Kysor</strong>//<strong>Warren</strong>.The above case model, has case lengths thatare UL and NSF approved.Issue: Sept - 06