QM3AG3– Multi-DeckApplication:37CASE DATA 04A 06A 08A 12AAnti-Sweat Amps N/A N/A N/A N/AFan Amps (SP) 0.35 0.70 0.70 1.05Light Amps (2 rows) 0.50 0.80 1.00 1.50Defrost Load Amps (If elec-230V) 3.30 5.61 7.93 11.54# Defrosts Required 4 4 4 4Evaporator Temperature °F +24° +24° +24° +24°BTU Requirements 3752 5628 7504 11256NOTE: For sizing conventional/individual condensing units ADD 8% to BTU LOAD.All electrical data based on 115V and unlighted shelves. For lighted shelves,Defrost Per Day Fail Safe TerminationOff Cycle 4 35 min 48°Hot gas 4 20 min 48°Electric 4 35 min 48°Discharge Air Velocity250 FPMDischarge Air Temp 29°FType I refrigerator, intended for use in an area where the environmental conditionsare controlled and maintained such that conditions do not exceed 75 deg Fand 55% relative humidity. <strong>Kysor</strong>//<strong>Warren</strong>, whose policy is one of continuousimprovement, reserves the right to change at any time, specifications, design orprices without incurring obligation.Dual-Jet and Air Defrost are registered trademarks of <strong>Kysor</strong>//<strong>Warren</strong>.The above case model, has case lengths thatare UL and NSF approved.Issue: Sept - 2006