11.07.2015 Views

1 Minutes of the 36th Meeting of the Expert Appraisal Committee ...

1 Minutes of the 36th Meeting of the Expert Appraisal Committee ...

1 Minutes of the 36th Meeting of the Expert Appraisal Committee ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The reconfiguration proposed is that <strong>of</strong> BF from 550 m 3 to 2015 m 3 , Coke Oven from 0.7 MTPAto 1.0 MTPA, Sinter plant from 60 m 2 to 204 m 2 , addition <strong>of</strong> new VD/AOD and lime plant <strong>of</strong> 600 TPDcapacity. The justification for above is that, scarcity in availability <strong>of</strong> quality raw material for DRIproduction resulting in lower production i.e. 1.8 MTPA in place <strong>of</strong> designed capacity <strong>of</strong> 2.4 MTPA. Tocompensate <strong>the</strong> shortage <strong>of</strong> DRI, additional hot metal (about 1.4 MTPA) is required. Hence, <strong>the</strong> highercapacity <strong>of</strong> BF. Accordingly, o<strong>the</strong>r facilities also need to be reconfigured. There is no additional landrequirement, no additional raw water to be drawn from <strong>the</strong> source and <strong>the</strong> additional power requirementwill be met through <strong>the</strong> existing CPP.The discussion and deliberations on <strong>the</strong> subject matter could not be completed and it wasdecided that <strong>the</strong> matter shall be taken up in <strong>the</strong> next meeting. The committee has also sought a detailedcomparative pollution load <strong>of</strong> various parameters due to <strong>the</strong> proposed reconfiguration.36.2.16 Ferro Alloy Plant with installation <strong>of</strong> 2 x 6.5 MVA Submerged Arc Furnace and manufacture 28,000 TPA <strong>of</strong> Fe-Mn and 19,000 TPA <strong>of</strong> Si-Mn and 9300 TPA <strong>of</strong> Fe-Si or 19,000 TPA <strong>of</strong> Ferro-Chrome at Sy. No: 15/E, Fouzpur Village, Taroda (B) Grampanchayat, Jainath Mandal,Adilabad District <strong>of</strong> Andhra Pradesh by M/s Balaji Electro Smelters Limited – regardingamendment in Environmental ClearanceThe proponent informed that <strong>the</strong>y will not be able to attend <strong>the</strong> meeting. The <strong>Committee</strong> decidedto consider <strong>the</strong> project as and when requested by <strong>the</strong> proponent.36.2.17 Expansion <strong>of</strong> Steel Plant (Unit-IV) by installation <strong>of</strong> Coke Oven Plant (Non-recovery type,1,65,000 TPA) along with Producer Gas Plant (9,000 Nm 3 /hr) and Captive Power Plant(WHRB, 9 MW & CFBC, 36 MW) at Village Banskopa, P.O. Rajbandh, District Burdwan, WestBengal by M/s Jaibalaji Industries Limited- regarding Amendment in EnvironmentalClearanceM/s Jaibalaji Industries Limited had obtained environmental clearance for Coke Oven Plant (Nonrecoverytype, 2,25,000 TPA) from SEIAA, West Bengal vide letter No. EN/82/T-II-I/077/2008, dated 20 thMarch, 2009 and for Coke Oven Plant (Non-recovery type, 1,65,000 TPA) from MoEF vide letter No.F.No. J-11011/496/2009-IA II(I), dated 29 th November, 2010. The PP has requested for amendment in<strong>the</strong> above ECs for <strong>the</strong> following:1. Revision <strong>of</strong> Coke Oven Plant Configuration i.e. installation <strong>of</strong> Coke Oven Plant (Non-recoverytype, 3,50,000 TPA) in place <strong>of</strong> Coke Oven Plant (Non-recovery type, 2,25,000 TPA) and CokeOven Plant (Non-recovery type, 1,65,000 TPA).2. Deletion <strong>of</strong> installation <strong>of</strong> ESP and GCT in EC condition since it is not required in <strong>the</strong> newtechnologyThe PP and <strong>the</strong>ir consultant, M/s. Envirotech East Pvt. Ltd., Kolkata have also made apresentation before <strong>the</strong> committee. It was submitted that, as per <strong>the</strong> technology available from M/s.China Shougang International Trade & Engineering Corporation (CSITEC) / Shanxi Provincial ChemicalDesign Institute (SPCDI), <strong>the</strong> following revision in <strong>the</strong> project configuration is required:Proposal obtained Environmental Clearance Revised ProposalSl.FeaturesNo.Coke oven Plant Coke oven PlantCoke oven Plant(2,25,000 TPA capacity) (1,65,000 TPA capacity) (3,50,000 TPA capacity)1. No. <strong>of</strong> ovens 55 33 802. Type <strong>of</strong> ovens Non-recovery type. Non-recovery type. Non-recovery type.3.WHRBsconnected toovens4 X 12 TPH 3 X 12 TPH 2 X 42 TPH4. StacksWHRBs2 No. each <strong>of</strong> 70 Mtrs.WHRBs1 No. <strong>of</strong> 50 Mtrs.41WHRBs2 No. <strong>of</strong> 70 Mtrs.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!