11.07.2015 Views

prerequisite bidding requirements - R & R Fire Truck Repair, Inc.

prerequisite bidding requirements - R & R Fire Truck Repair, Inc.

prerequisite bidding requirements - R & R Fire Truck Repair, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Demo #3709 Smeal <strong>Fire</strong> Apparatus Co. 75’ Heavy Duty AerialCONTRACTOR'S SPECIFICATIONSEach bid shall be accompanied by a set of "Contractor's Specifications" consisting of a detaileddescription of the apparatus and equipment proposed to which the apparatus, furnished undercontract, must conform.These specifications shall indicate size, type, model, and make, of all component parts andequipment.The submitted bids must clearly describe the capabilities of the aerial device. Items such as safetyfactor certification, horizontal reach, vertical reach, scrub chart information, load capabilities, flowratings, monitor capabilities, short set capabilities, safety interlock information, estimatedcompleted weight information and other pertinent information must be either submitted with the bidor readily available if requested.TIMELY PROPOSALSIt is the bidder's responsibility to see that their proposals arrive on time. Late proposals, facsimiles,e-mails, telegram, or telephone bids shall not be considered.DRAWINGSAll bid drawings will be stamped PRELIMINARY DRAFT. A total of six (6) “C” size drawings and one (1) 11” x 17” drawing will be supplied. All drawings will be drawn and printed in a 3/8 to 1 scale. Compartment door opening dimensions will be shown on table on the drawing which will referto each compartment number, such as L1, R1, T1. Drawings will be five (5) view. (Left, Right, Front, Rear, Top) with the exception of chassis thatare not always available as AutoCad drawings. Rear plumbing, such as 2-1/2” discharges, rear steamers and direct tank fills, will be shown. Ladders will be labeled with a letter designation referring to the table for an explanation of theladder type. OAL (Overall Length) in Feet & <strong>Inc</strong>hes. -Estimated length will be rounded up to the nearest inch. OAH (Overall height) in Feet & <strong>Inc</strong>hes.Estimated height will be rounded up to the nearest inch. Body dimensions shown - pump house width & front of the body to centerline of the rear axle. Wheelbase in inches Front and rear overhang in inches. No Pump Panel or Instrument Panel, controls, discharges or inlets. To be blank andlabeled“Pump Panel”. Water tank outline. Foam tank(s) fill towers. Outrigger side view, no hidden beam lines.Revised 6/2/09 Page 3 of 114

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!