8. TROUBLESHOOTINGProblem Possible cause RemedyThe automation does not open No power.Check that the control panel is on (the POWERand close.ALARM led must be on).Accessories in short circuit.(LED POWER ALARM flashing)Disconnect all the accessories from the terminals0-1 (24 V= are required) and reconnect these oneat a time.Line fuse burnt out. Replace the fuse F1.The stop contact is openCheck terminal 9 of the control panelThe automation opens but does The safety contacts are open.Check terminal 8 of the control panel.not close(LED SA on).The photocells (if fitted) are triggered.(LED SA on).Make sure the photocells are clean and workingproperly.Automatic closing does not work.Check the setting of the TC trimmerThe automation fails to open. The automation is closed and the photocells (if Make sure the photocells are clean and workingfitted) are operative.(LED SA on).properly.See jumper SO.Remote control does not work.Make sure the transmitters have been properlystored on the built-in radio receiver. In case offailure of the radio receiver built in the controlpanel, the remote control codes can be accessedby extracting the memory module.Command devices faulty or connections Check opening by means of jumper 1-5 of theinterrupted.terminal board control panel.The external safety devices (iffitted) fail to operate.Wrong connections between the photocells andthe control panelThe automation opens/closes Encoder faulty.for a short distance and then (LED POWER ALARM flashing).stops.Motor leads reversed.(LED POWER ALARM flashing).There are frictions.The radio remote control has alow range and does not workwith the automation in motion.Encoder not connected.False encoder contacts.R1 set too low.Radio transmission is hampered by metalframeworks and reinforced concrete walls.Connect the N.C. safety contacts together in seriesand remove any jumpers on the terminal board ofthe control panel.Replace the encoder.Check the motor leads.Manually make sure the automation is movingfreely.Check the connection.Clean the contacts by engaging and disengagingthe encoder plug on the contacts.Check R1 adjustment.Install the antenna outside. Replace the batteriesof the transmitters.GB23 GLOBE - IP1839

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!