11.07.2015 Views

Installation Manual - Unical Lattner Condensing Hot Water Boilers

Installation Manual - Unical Lattner Condensing Hot Water Boilers

Installation Manual - Unical Lattner Condensing Hot Water Boilers

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3INSTRUCTIONS FORTHE INSTALLERInstructions for the installer3.1 - GENERAL WARNINGSWARNING!This boiler has to be destined for the use forwhich it has been expressively designed for.Any other use shall be considered improperand therefore dangerous.This boiler is designed to heat water at atemperature inferior to boiling point at anatmospheric pressure.WARNING!These appliances are exclusively designedto be installed inside adequate boiler rooms.Therefore these appliances must not beinstalled and operated externally. An outdoorinstallation could cause malfunctioning andcould be dangerous. For externalinstallations, it is recommended to useappliances which are specifically designedand predisposed for this purpose.Before installing the boiler the following pointshave to be carried out by a competent engineer:a) The whole system should be thoroughlyflushed in order to remove any residual dirt orgrime which could compromise the correctboiler operation.b) Check that the boiler has been preset foroperating with the gas type available.This is verifiable via the indication on thepackaging and on the data badge;c) Check that the chimney/flue pipe has anadequate draught,does not have anyconstrictions, and that no other appliance’s flueoutlets have been fitted, unless the chimneyis serving more than one heating appliance,according to the specific standards andregulations in force.The connection between the boiler andchimney/flue outlet can be made only after thisverification has been carried out.WARNING!In rooms where there is the presence ofaggressive vapours or dust the appliancemust operate independently from the airpresent in the boiler’s location room!WARNING!The appliance must be installed by a qualifiedengineer, who complies to the technicalprofessionalrequirements, who, under his ownresponsibility, guarantees the compliance ofthe standards according to the latestregulations.WARNING!The appliance must be positioned so that atleast the minimum operational and servicingclearances are provided.The boiler must be connected to a heating system which iscompatible to its performance and output.Before boiler installation, complete all of thefollowing instructions:The installation must conform to the requirements of theauthority having jurisdiction or, in the absence of suchrequirements, to one of the following:- United States - <strong>Installation</strong> must conform to the requirementsof the National Fuel Gas Code, ANSI Z223.1/NFPA 54.- Canada - <strong>Installation</strong> must conform to the requirements ofCAN/CSA-B149.1 - Natural Gas and Propane <strong>Installation</strong>CodeWhere required by the authority having jurisdiction, theinstallation must conform to the Standard ASME CSD-1Controls and Safety Devices for Automatically Fired <strong>Boilers</strong>NOTES:- Installers must follow local regulations with respect toinstallation of Carbon Monoxide (CO) Detectors. Also, followthe maintenance recommendations in this manual.- FOR MASSACHUSETTS INSTALLATIONS: The boiler mustbe installed by a plumber or gas fitter licensed within theCommonwealth of Massachusetts.13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!