Instructions for the installerThe flue system must be installed inaccordance with the local and nationalStandards.Use only original LATTNER flue outlet systems, which areprovided from the follow manufacturer:TABLE FLUE OUTLET SYSTEM3.18 - ROOM AIR SYSTEMFOR INSTALLATION USING INDOORCOMBUSTION AIRBoiler designed to be connected to an open flue which willterminate vertically through the roof. The combustion air iswithdrawn directly from the room where the boiler is installed.ItemDecriptionVentingpipe3.28 ftManufacturerSTABILEMaterialStainlessSteelCode LATTNER00362448WARNING: for this type of connection the room must complywith the same installation regulations valid for openchimney boilers.The chimney must comply to the current regulations.Ventingpipe1.62 ftSTABILEStainlessSteel00362449Elbow 90°STABILEStainlessSteel00362450Elbow 45°STABILEStainlessSteel00362451HorizontalFlue terminalVerticalFlueTerminalGROPPALLISTABILEAlluminiumStainlessSteel0036149300362452When using indoor air, LATTNER strongly recommends theuse of an indoor air filter.This boiler requires adequate combustion air for ventilationand dilution of flue gases.Failure to provide adequate combustion air can result in unitfailure, fire, explosion, serious bodily injury or death.Use the following methods to ensure adequate combustionair is available for correct and safe operation of this boiler.Damages caused by installation errors and for nonobservanceof the instructions given by the manufacturerwill invalidate all the supplier’s contractual or extracontractual responsibilities.If the boiler has to be replaced ALWAYS replace the flueoutlet system.The boiler has been tested and approved with the terminalsdistributed by <strong>Lattner</strong> that comply the requirements of ANSIZ21.13 / CSA 4.9 for the following flue configurations.Important: Combustion air must be free of corrosive chemicals.Do not provide combustion air from corrosive environments.Appliance failure due to corrosive air is not covered bywarranty.Combustion air must be free of acid forming chemical such assulfur, fluorine and chlorine. These chemicals have been foundto cause rapid damage and decay and can become toxic whenused as combustion air in gas appliances. Such chemicalscan be found in, but not limited to bleach, ammonia, cat litter,aerosol sprays, cleaning solvents, varnish, paint and air fresheners.Do not store these products or similar products in thevicinity of this boiler.Flue outlet systems must be purchasedfrom the dealer of products LATTNER.27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!