11.07.2015 Views

2012 Activity and sustainable development report - RTE

2012 Activity and sustainable development report - RTE

2012 Activity and sustainable development report - RTE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ENVIRONMENTAL DATA<strong>RTE</strong> has been ISO 14001 certified for all its activities since 2004. Afnor has renewed <strong>RTE</strong>’s ISO 14001 certifi cate for the periodfrom June <strong>2012</strong> to December 2013.<strong>2012</strong> 2011 1 2010Protected natural zones, biodiversityTotal length of network: overhead <strong>and</strong> underground transmission connections104,040 104,144 104,252in operation – voltage equal to or higher than 63 kV (in km)Total surface area occupied by the network (in hectares) 400,000 400,000 400,000Farml<strong>and</strong> (in km) 60,102 not disclosed not disclosedForest zones (in km) 17,087 not disclosed not disclosedProtected natural zones (in km) 34,574 not disclosed not disclosedNatura 2000 zones (in km) 9,051 not disclosed not disclosedDevelopment projects encouraging biodiversity (number) 57 not disclosed not disclosedCumulative area developed for biodiversity (in hectares) 353 not disclosed not disclosedGreenhouse gas emissions (in tCO 2e) - BRGES 2Scope 1 (Direct emissions within the scope) 156,586 Not availablein regulatoryformatScope 2 (Indirect emissions relating to energy, for <strong>RTE</strong> primarily consumptionrelating to losses of electricity)620,032 Not availablein regulatoryformatScope 3 (Other indirect emissions) 485,613 Not availablein regulatoryformatElectricity losses on the networkElectricity purchases to offset losses on the network (in TWh) 10.52 11.0 11.9Rate of losses: ratio between the consumption of electricity offsetting the losses<strong>and</strong> the total energy injected into the network (%)2.08 2.13 2.23Accidental oil leaks 3Volume of unrecovered oil – Underground lines (in m 3 ) 46.7 11.3 33Volume of unrecovered oil – Transformers <strong>and</strong> substations (in m 3 ) 5.2 8.9 5.2Recovery rate (%) 51 64 501. Data published with respect to the 2011 fi nancial year has been restated for impact linked to the change of accounting method of actuarial gains <strong>and</strong> losses relating to postretirementbenefi t obligations. 2. <strong>RTE</strong> has taken a proactive approach since 2008, carrying out a greenhouse gas balance for the fourth year in succession. The inventory was carriedout according to the carbon balance method, which is compatible with the regulatory greenhouse gas balance made compulsory in <strong>2012</strong> for French companies with more than500employees. In accordance with regulations, the next inventory will be conducted in 2015, on the basis of operations in 2014. 3. Explanation of the difference between 2011 <strong>and</strong><strong>2012</strong>: a 36m 3oil leak occurred on the underground Anglo-French IFA 2000 link in <strong>2012</strong>.84

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!