CALIBRATECONFIGURATION SET ANALOG FORMAT SETPOINTS SERIAL DIGITAL IN ANALOG OUT BAR GRAPH(CALIBRATION)CALIBRT(CHANNEL 1 CALIBRATION)CHAN 1(CHANNEL 2 CALIBRATION)CHAN 2(CHANNEL 3 CALIBRATION)CHAN 3(CHANNEL 4 CALIBRATION)CHAN 4IDENTICAL PROCEDURE ASFOUND UNDER CHAN 1IDENTICAL PROCEDURE ASFOUND UNDER CHAN 1IDENTICAL PROCEDURE ASFOUND UNDER CHAN 1➡➡➡(WEIGHT CALIBRATION)WEIGHT(VOLTS CALIBRATION)VOLTSCalibrated at factory. Do NOTchange calibration values underthe "VOLTS" menu.(ZERO WEIGHT CAL)W ZERO(WEIGHT VALUE CAL)W VAL(SPAN WEIGHT CAL)W SPAN(ZERO VOLTS CAL)V ZERO(WEIGHT VALUE CAL)V VAL(SPAN VOLTS CAL)V SPAN(CLEAR SCALE ANDPUSHENTER)(ENTER TEST WEIGHTVALUE)XXXXX(PLACE TEST WEIGHTON SCALE AND PUSHENTER)(ENTER 0 VOLTS ORPUSH ENTER TOCALCULATE)(ENTER CAL WEIGHTVALUE)XXXXX, PUSH ENTER(ENTER SPAN VOLTSOR PUSH ENTER TOCALCULATE)Detailed directions for calibration procedures are found in Section 8, Calibration.6 - 17
6.1 MENU DESCRIPTIONSCONFIGURATION MENU DESCRIPTIONS (Defaults in Bold Type with √)NAME DESCRIPTION CHOICESGRADS 1Graduations. This parameter specifies the number of full scalegraduations. The value entered should be consistent with legalrequirements and environmental limits on the useful system resolution.Enter value with numerical keyboard then exit upward to enterthe new value.This parameter, and the first three parameters (DSP DIV, DEC PNT,and UNITS) under Primary Scale in the FORMAT 1st level menu,define the scale capacity. For example, if GRADS = 10,000, DSP DIV =5, DEC PNT = 88888.88, and UNITS = LB, then the scale capacity is500.00 LB in .05 increments0 to 100,000Default = 10,000 √GRADS 2 Same as GRADS 1 for the optional input channels 2-4.GRADS 3GRADS 4Same as GRADS 1ZTRKBNDZRANGEMOTBANDOVRLOADZero Track Band. Automatically zeroes the scale when it is within therange of selected values, as long as the input is within the ZRANGE,and the scale is in standstill. Selections are ± DD. Maximum legalvalue varies depending on local regulations.Zero Range. Selects the range within which the scale may bezeroed. The 1.9% selection is ±1.9% around the calibrated zeropoint, for a total range of 3.8%. Indicator must be in standstill to zerothe scale. Use 1.9% for Legal-For-Trade applications.Motion Band. Sets the level at which scale motion is detected bycomparing the present display update with the previous update. Ifmotion is not detected for 1 second or more, the standstill symbollights and the scale can process a Print command. Maximumlegal value varies depending on local regulations.Overload. Determines the point at which the display blanks and anerror message is displayed, indicating an out-of-range condition.Maximum legal value varies depending on local regulations.OFF√ 0.5 D1 D 3 D1.9%√ 100%1 D√3 D5 D10 DFS FS + 2%√FS + 1D FS + 9DPWR UPPower Up Mode. In the GO mode, the scale goes into operationimmediately after a brief power up display test. In the DELAY mode,the scale does a power up display test, then must warm up (WARMUP and the standstill symbol are displayed) with no motion detectedfor 30 seconds before going into operation. If motion is detectedwithin that period, the 30-second sequence restarts. The delay isused where local regulations require a warm-up period.GO√DELAY200TARE200 ID/Tare Truck In/Out Mode. If enabled by selecting one of the sixTruck In/Out modes, the indicator shifts from the Normal <strong>Weighing</strong>Mode into the truck mode selected. See Section 3.4.MODE 1: Auto Clear ID, Keyed Tares, Value SwappingMODE 2: Auto Clear ID, No Keyed Tares, Value SwappingMODE 3: Stored ID, Keyed Tares, Value SwappingOFF√MODE 1MODE 2MODE 3MODE 4MODE 5MODE 66 - 18