Pre-Installation Items- Reference the appropriate vent supplementfor clearance requirements.BEST PRACTICETo provide serviceability to the unit it isrecommended that the following clearancesbe maintained:Top boiler jacket - 24 inches [610 mm].Front - 24 inches [610 mm].Bottom boiler piping - 24 inches [610mm].Rear - 0 inchesSides - 6 inches [153 mm]WARNINGIf the clearances listed above cannot bemaintained or the enclosure in which theboiler is <strong>install</strong>ed is less than 85 cubic feet,the space must be ventilated. See page 6for ventilation requirements.NOTICEWhen maintaining zero clearance or lessthan recommended clearances, someproduct labeling may become hiddenand unreadable.Residential Garage InstallationsWhen <strong>install</strong>ing the PRESTIGE <strong>Solo</strong> in a residentialgarage, the following special precautionsper NFPA 54/ANSI Z223.1 must be taken:- Mount the unit a minimum 18 inches[458 mm] above the floor level of thegarage. Ensure the burner and ignitiondevices / controls are no less than 18inches [458 mm] above the floor level.- Locate or protect the unit in a manner so itcannot be damaged by a moving vehicle.Boiler Freeze Protection FeatureThe TriMax boiler management system has afreeze protection feature built in. This featuremonitors the boiler temperature and responds asfollows when no call for heat is present:- 46ºF [8ºC] CH (1) & Auxiliary BoilerPumps ON- 42ºF [6ºC] CH (1), Auxiliary Boiler &System Pumps ON, Burner operates atlow fire- 60ºF [15ºC] Freeze protection ends.Burner & all pumps OFF after completingCH Post Pump Time.CAUTIONThe boiler freeze protection feature isdisabled during a hard lockout, howeverthe circulators will operate.WARNINGWhen <strong>install</strong>ing the PRESTIGE <strong>Solo</strong> ina confined space, sufficient air must beprovided for proper combustion andventing and to allow, under normal operatingconditions, proper air flow aroundthe product to maintain ambient temperatureswithin safe limits to complywith the National Fuel Gas Code NFPA54 - latest edition.CAUTIONThe boiler freeze protection feature isdesigned to protect the boiler. The boilershould be <strong>install</strong>ed in a primary/secondarypiping arrangement if it is<strong>install</strong>ed in an unheated space orexposed to water temperatures of 46ºF orless. See Section IV for primary/secondarypiping examples. See Section Xfor antifreeze guides.4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!