11.07.2015 Views

Prestige Trimax Solo 60175250399 install manual - Coastal Winair

Prestige Trimax Solo 60175250399 install manual - Coastal Winair

Prestige Trimax Solo 60175250399 install manual - Coastal Winair

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Combustion Air VentingVentilation and Combustion AirRequirements - Direct VentA Direct Vent appliance utilizes uncontaminedoutdoor air (piped directly to the appliance) forcombustion.For Direct Vent <strong>install</strong>ations, involving onlythe PRESTIGE <strong>Solo</strong>, in which the minimumservice clearances are maintained as listed onpage 4, no ventilation openings are required.For Direct Vent, zero clearance <strong>install</strong>ationsinvolving only the PRESTIGE <strong>Solo</strong>, the space/ enclosure must provide two openings for ventilation.The openings must be sized to provide1 square inch of free area per 1,000 BTUH ofboiler input. The openings shall be placed 12inches from the top of the space and 12 inchesfrom the floor of the space.For <strong>install</strong>ations in which the PRESTIGE <strong>Solo</strong>shares the space with air movers (exhaust fan,clothes dryers, fireplaces, etc.) and other combustionequipment (gas or oil) the space mustbe provided with adequate air openings to provideventilation and combustion air to theequipment. To properly size the ventilation /combustion air openings, the <strong>install</strong>er mustcomply with the National Fuel Gas CodeNFPA 54, ANSI Z223.1 for <strong>install</strong>ations in theU.S or CSA B149.1 and B149.2 for <strong>install</strong>ationsin Canada.WARNINGThe space must be provided with ventilation/ combustion air openings properlysized for all make-up air requirements(exhaust fans, clothes dryers, fireplaces,etc.) and the total input of all applianceslocated in the same space as the PRES-TIGE <strong>Solo</strong>, excluding the input of aDirect Vent PRESTIGE <strong>Solo</strong> which usescombustion air directly from the outside,thus additional free area for the openingsis not required. Failure to provideor properly size the openings couldresult in severe personal injury, death orsubstantial property damage.Ventilation and Combustion AirRequirements - Category IVA Category IV appliance utilizes uncontaminatedindoor or outdoor air (surrounding theappliance) for combustion.BEST PRACTICEIn order to reduce the potential risksassociated with indoor contaminates(listed on page 5), flammable vapors andtight housing construction (little or noinfiltration air), it is recommended topipe uncontaminated combustion airdirectly from the outdoors to the appliance.This practice also promotes highersystem efficiency by reducing heatedindoor air from being exhausted fromthe house and replaced by cold infiltrationair into the house.For <strong>install</strong>ations in which the PRESTIGE <strong>Solo</strong>shares the space with air movers (exhaust fan,clothes dryers, fireplaces, etc.) and other combustionequipment (gas or oil) the space mustbe provided with adequate air openings to provideventilation and combustion air to the equipment.To properly size the ventilation / combustionair openings, the <strong>install</strong>er must complywith the National Fuel Gas Code NFPA 54,ANSI Z223.1 for <strong>install</strong>ations in the U.S or CSAB149.1 and B149.2 for <strong>install</strong>ations in Canada,as referenced in this section of the <strong>manual</strong> andtitled Methods of Accessing Combustion Airinto a Space.WARNINGThe space must be provided with ventilation/ combustion air openings properlysized for all make-up air requirements(exhaust fans, clothes dryers, fireplaces,etc.) and the total input of all appliances,including the PRESTIGE <strong>Solo</strong> whenlocated in the same space. Failure to provideor properly size the openings couldresult in severe personal injury, death orsubstantial property damage.6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!