[c] CONTROLS AND ADJUSTMENTSa) Default Dip Switch SettingsThe dip switch is factory-adjusted to the following positions:<strong>KMD</strong>-<strong>201AA</strong>(50Hz)<strong>KMD</strong>-<strong>201AA</strong>(60Hz)<strong>KMD</strong>-<strong>201AWA</strong>(50Hz)<strong>KMD</strong>-<strong>201AWA</strong>(60Hz)<strong>KMD</strong>-<strong>201AA</strong>(50Hz)<strong>KMD</strong>-<strong>201AA</strong>(60Hz)<strong>KMD</strong>-<strong>201AWA</strong>(50Hz)<strong>KMD</strong>-<strong>201AWA</strong>(60Hz)Do not adjust the S2 dip switch. These must be left in the factory default position, or the unitwill not operate properly.b) Harvest Timer (S1 dip switch 1 & 2)Used for adjustment of the harvest timer. The harvest timer starts counting when thethermistor reads a certain temperature at the evaporator outlet.12