12.07.2015 Views

Review of the Air Quality Criteria Document for Particulate Matter

Review of the Air Quality Criteria Document for Particulate Matter

Review of the Air Quality Criteria Document for Particulate Matter

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

same tidal volume <strong>of</strong> 500 mL at 15 breaths/min, and this means <strong>for</strong> women, generally smallerthan men, an increased minute ventilation compared to <strong>the</strong>ir normal breathing condition.There<strong>for</strong>e, gender-related differences in deposition found here may be due to <strong>the</strong> fact thatwomen brea<strong>the</strong>d at a relative larger minute ventilation and would not show if both men andwomen would breath at <strong>the</strong>ir normal size-adjusted tidal volumes. A critical discussion along thisline should be added.Line 13: It would be helpful to add here a summarizing paragraph since <strong>the</strong>reviewed studies on gender differences show somewhat differing results and it would beappropriate to have a summarizing concluding statement.Page 7-20, lines 1-2: When comparing deposition efficiencies in <strong>the</strong> lungs <strong>of</strong> childrenvs. adults, it should also be considered that children have a higher minute ventilation per unitbody weight compared to adults.Line 26: Again, a summarizing paragraph would be helpful regarding age-relateddeposition differences.Page 7-25, line 17: ">5 µm" should be "