Installation Manual - Unical Lattner Condensing Hot Water Boilers

Installation Manual - Unical Lattner Condensing Hot Water Boilers

Installation Manual - Unical Lattner Condensing Hot Water Boilers

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Fault finding5.2 - DISPLAY OF ERROR CODES ON HEATING CONTROLLER E8Cod:Mining:24E30Alteration of the operating parameterscaused by EMC disturbances18126E32Mains supply voltage < 190 VacIn case of fault, on the display of the regulator a blinking trianglewith its error code will appearHere below you will find the E8 error codes, the relevantmeaning and corrective actions.Cod:E01E02E04E05E06E08Mining:Intervention of the high limit thermostat (TL)Insufficient gas pressureNo flame detected during the ignition phaseLost of the flame signal during the operationToo high water temperature detected by theheating sensor (SR) (> 95°C)Lack of waterE69E70E71E72E75E76E78E80E81E8: F5 – Flow temperature sensor heatingcircuit 2E8: F11 – Flow temperature sensor heatingcircuit 1E8: F1 – Lower storage temperature sensor(Buffer)E8: F3 – Higher storage temperaturesensor (Buffer)E8: F9 – Outer temperature sensor (AF)E8: F6 – DHW storage temperature sensor(SPF)E8: F8 – Boiler temperature sensor (KF)E8: F2 – Room temperature sensor heatingcircuit 1E8: EEPROM fault. The invalid value hasbeen replaced by the standard valueE10E11E12Internal faultFlame detected before the starting of theignition cycleFault at the heating flow sensor (SR)E83E90E8: F15 – Room temperature sensorheating circuit 2E8: BUS addresses 0 and 1. The BUScodes 0 and 1 cannot be used at the sametime.E13Fault at the DHW sensorE91E8: BUS code occupied. The set BUS codeis already used by another applianceE14Fault at the heating return sensor (SRR)E99E8: Internal failureE15E16E20E24Temperature difference between heating flowtemp. sensor (SR) and heating return temp.sensor (SRR) is > 35KBoiler water is frozenFlame detected after burner extinctionModulating fan speed failure: it doesn‘t reachthe correct speed within 30 s from starting ofburnerignition cycleE135E8: F12 – Lower DHW storage temperaturesensor MF2E136 E8: F13 – Boiler 2, Manifold 2 MF 3E137 E8: F14 – Manifold 1, Multifunction 4.E200E8: Intervention os safety devices (fansrotating at maximum speed) /communication error module 152

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!