7 Appendix: NSC mix designsTable 7.11st mix for the splitting tensile testCoarseDry weight <strong>of</strong> Coarse 196.2 196.2SSD wt <strong>of</strong> Coarse 199.7 lbs Coarse aggregate distributionWater abs by coarse 1.9 lbs wt% dry moistFree Water onCoarse 4.4 lbs 3/4 0.0 0.0 0.01/2 0.0 0.0 0.0Fine 3/8 50.0 98.1 98.4Dry Fine Agg Wt 140.1 lbs no. 4 45.3 88.9 89.1Moist Fine Agg Wt 143.6 lbs no. 8 4.7 9.2 9.2SSD Wt <strong>of</strong> Fine 141.3 lbs no. 16 0.0 0.0 0.0Free Water on Fine 2.3 lbs 100.0 195.9 196.8WaterTesting dataWater Wt 35.7 lbsTemp.(C) 71.6Corrected Water Wt 28.9 lbsSlump(in.) 5.8vinsol AEA 18.0 ml Pressurewater reducer 30.0 ml meter airvol% 5.7CementitiousPortland 79.5 lbsUnitweight(lbs/ft3) 145.2Fly Ash 0.0Yield(ft3) 3.1GGBFS 0.0C<strong>as</strong>t samplesSplitting tensile samples in dry conditions (15 beams for 0 F-T cycles and 15beams for 300 F-T cycles)Date10/21/2010112