12.07.2015 Views

Modular FRL Unit Series AC - SMC

Modular FRL Unit Series AC - SMC

Modular FRL Unit Series AC - SMC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Series</strong> <strong>AC</strong>Pressure Switch (S)A compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line.IS1000M30JIS SymbolPressure switchOptionSpecificationsSymbol-P Note)X202X202-P Note)X201X201-P Note)X215X215-P Note)FluidAmbient and fluid temperatureProof pressureMaximum operating pressureSet pressure range (when OFF)HysteresisSwitch CharacteristicsContact point configurationMaximum contact point capacityOperating voltage: <strong>AC</strong>, DCMaximum operating currentLead wire length0.5 m0.5 m0.5 m0.5 m3 m3 m3 m3 mDescriptionSetpressure range0.1 to 0.4 MPa0.1 to 0.4 MPa0.1 to 0.6 MPa0.1 to 0.6 MPa0.1 to 0.4 MPa0.1 to 0.4 MPa0.1 to 0.6 MPa0.1 to 0.6 MPaNote) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)Air–5 to 60°C (with no freezing)1.0 MPa0.7 MPa0.1 to 0.4 MPa0.08 MPa or less1a2 VA(<strong>AC</strong>), 2 W(DC)100 V or less2 V to 24 V<strong>AC</strong>, DC : 50 mA48 V<strong>AC</strong>, DC : 40 mA100 V<strong>AC</strong>, DC : 20 mANote) For detailed specifications, please refer to Best Pneumatics, IS1000 <strong>Series</strong>.T-interface (T) M5, 1/8, 1/4, 3/8, 1/2Pressure displayMPaMPa/PSI dual scaleMPaMPa/PSI dual scaleMPaMPa/PSI dual scaleMPaMPa/PSI dual scaleBody size20 30 40 50 60ModelIS1000M-20IS1000M-30IS1000M-40IS1000M-50IS1000M-60A1113151722B7686959992.5BC66727779C68.5D283036445323Note) Separate spacers are required for modular unit.D≈ 500Centre ofF.R.L. bodyApplicable model15A<strong>AC</strong>20<strong>AC</strong>25, <strong>AC</strong>30<strong>AC</strong>40<strong>AC</strong>40-06<strong>AC</strong>50, <strong>AC</strong>55, <strong>AC</strong>60Using a T-interface facilitates the redirection of air flow.Port sizeEOctagonT-interfaceBCDCentre ofF.R.L. body<strong>AC</strong>aution on MountingIf a T-interface is used on the IN side of the lubricator, lubricantmay be mixed. Use the AKM series check valve to avoid such apossibility.23ModelY110-M5Y210-01Y210-02Y310-01Y310-02Y410-02Y410-03Y510-02Y510-03Y610-03Y610-04Port sizeM51/81/41/81/41/43/81/43/83/81/2A111515191922B194253626681Applicable model<strong>AC</strong>10, <strong>AC</strong>10B<strong>AC</strong>20, <strong>AC</strong>20B,<strong>AC</strong>20C<strong>AC</strong>25, <strong>AC</strong>25B,<strong>AC</strong>25C, <strong>AC</strong>30,<strong>AC</strong>30B, <strong>AC</strong>30C<strong>AC</strong>40, <strong>AC</strong>40B,<strong>AC</strong>40C<strong>AC</strong>40-06. <strong>AC</strong>40B-06<strong>AC</strong>40C-06<strong>AC</strong>50, <strong>AC</strong>55,<strong>AC</strong>60, <strong>AC</strong>50B,<strong>AC</strong>55B, <strong>AC</strong>60BNote 1) in model numbers indicates a thread type. No indication is necessary for Rc;however, indicate N for NPT, and F for G.Note 2) Separate interfaces are required for modular unit.∗ Refer to the attachment table on page 22 for standard port sizes when using with the <strong>AC</strong>.C123239444657D142830364453E81919242430

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!