F. Installing the Flame SolenoidGas ControlValveKnobScrewWasherVariableRegulatorNutWasherVariableRegulatorSolenoidFlame ControlSolenoidVariableRegulatorPlungerJam NutFigure 10.3 Install the Flame Solenoid• Remove the screw and knob from the variable regulatorand discard.• Remove the nut from the regulator and discard.• Remove the bag containing a washer and blue and redplungers from the side of the fl ame control solenoid.• Place washer on flame control solenoid. SeeFigure 10.3.• Insert the correct plunger (blue - natural gas, red - propane)into the fl ame control solenoid. See Figure 10.3.• Thread the flame control solenoid with correct plunger intothe thread hole in the variable regulator. Turn into valveapproximately two full turns. Do not tighten or damagemay occur.• Connect orange wires from control box to the flame controlsolenoid.G. Hook up the Temperature Sensor Switch for Fan• Find the two yellow wires from the WSK-MLT control boxand disconnect them.• Connect one yellow wire to one jumper wire hanging fromthe thermodisc.• Connect the other yellow wire to remaining jumper wirehanging from thermodisc.• See Figure 10.2 for wiring diagram.Heatilator • Caliber CNXT Series • 4047-132 Rev O • 09/07 47