DisplayThe Main Display has 9 characters (7 seven--segmentcharacters and 2 nine--segment characters), 2 decimalpoints, 2 commas, and a degree symbol. The display isused to provide the user setpoint and refrigeratedcompartment temperatures, either in degreesCentigrade or Fahrenheit. The comma symbols areused as the decimal indicators in Europe. When MetricUnits is selected in the Functional Parameters, the twocomma icons are used instead of decimal points. WhenEnglish Units is selected in the Functional Parameters,decimal points are used.Temperature display is right justified, with unused digitsblank. A negative sign will be displayed for all setpointand box temperatures below zero. A positive sign will bedisplayed for all setpoint and box temperatures above0°F (--17°C). 0° will not have a sign in front of it.Indicator LEDsThe display has six LEDs across the top to indicateoperation status. These indicators are:Cool Indicator (Green) -- Turned on when the unit is inCool Mode.Heat Indicator (Amber) -- Turned on when the unit is inHeat Mode.Defrost Indicator (Amber) -- Turned on when the unit is inDefrost Mode.Start--Stop Indicator (Green) -- Turned on when theStart--Stop Mode has been selected.Continuous Indicator (Green) -- Turned on when theContinuous Mode has been selected.Alarm Indicator (Red) -- Off or Flashes at a rate of 0.5seconds.NOTEWhen the unit is in Null mode (fan only), themode indicators (cool, heat and defrost) are alloff.NOTEThere is an opening between the Alarm andStart--Stop LEDs that is not used at this time.MessageCenterThe MessageCenter is used to show messages. Detailsof the messages are described in Section 6.1MessageCenter.NOTEMessages can be displayed in multiple languages.See Section 3.17 for Functional Parametersettings.Switch Descriptionsa. ENGINE/STANDBY Switch (SS)This switch is used to select mode ofoperation, either engine drive or standbyelectric motor drive. When this switch isplaced in standby position, the electricmotor will not start until the oil pressuresafety switch (ENOPS) opens.b. START/RUN -OFF Switch (RS)When placed in the RUN position, thisswitch provides power to themicroprocessor. The microprocessorperforms a self-test (all segments ofdisplay are illuminated). Then setpoint andBox Temperature are displayed.To stop the unit or remove power fro<strong>mt</strong>he microprocessor, move the RS to theOFF position.c. REMOTE COMPARTMENT SWITCHESOn/Off toggle switches located above the display.Placing a switch in the “ON” (I) position starts remoteevaporator in that compartment.62-110392--16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!