MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products
MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products
MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Data CommandsClear TotalsDescription: Resets the totals to zero.Command FormatOutput Byte Modbus Description Name Range MLAN Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 76 Slave Address MLAN Address7 Function Code 168 Register Hi Command Code 24 Clear Totals Command9 Register Lo 010 Register Count Hi 011 Register Count Lo 012 Data Byte Count 0Response FormatInput Byte Modbus Description Name Range Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 26 Slave Address MLAN Address7 Function Code 16 Top bit set on errorNOTE:The totals will not be erased until the end of the current cycle. If the blender is idle,the totals will be cleared at the end of the next cycle.15