12.07.2015 Views

MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products

MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products

MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Set Weight UnitsDescription: Sets the units that the blender uses to display totals, such as poundsor kilograms.Command FormatOutput Byte Modbus Description Name Range MLAN Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 96 Slave Address MLAN Address7 Function Code 168 Register Hi Command Code 86 Set Weight Units Command9 Register Lo 010 Register Count Hi 011 Register Count Lo 112 Data Byte Count 213 Data Word 0 Hi Weight units 014 Data Word 0 Lo Weight units 0, 1, 2, or 40=pounds, 1=ounces,2=grams, 4=kilogramsResponse FormatInput Byte Modbus Description Name Range Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 26 Slave Address MLAN Address7 Function Code 16 Top bit set on error58