Get Target Throughput & StatusDescription: Returns the target throughput rate for extrusion control.See XCV parameter in blender manual for more information.Command FormatOutput Byte Modbus Description Name Range MLAN Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 66 Slave Address MLAN Address7 Function Code 3 or 48 Register Hi Command Code 29Get Target Throughput &Status Command9 Register Lo 010 Point Count Hi 011 Point Count Lo 3Response FormatInput Byte Modbus Description Name Range Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 96 Slave Address MLAN Address7 Function Code 3 or 4 Top bit set on error8 Byte Count 69 Data Word 0 Hi Status 010 Data Word 0 Lo Status 255 See note 111 Data Word 1 Hi Steady State Rate12 Data Word 1 Lo Steady State Rate13 Data Word 2 Hi Steady State Rate14 Data Word 2 Lo Steady State RateNote 1 – Status0 to4294967295Grams (or tenths of grams)per hourBIT Name Value Description0 Extrusion control 1=on Bit 0 is the rightmost bit33