MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products
MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products
MODBUS TCP/IP PROTOCOL MANUAL - Maguire Products
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Get Steady State RateDescription: Returns throughput rate.Command FormatOutput Byte Modbus Description Name Range MLAN Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 66 Slave Address MLAN Address7 Function Code 3 or 48 Register Hi Command Code 64Get Steady State RateCommand9 Register Lo 010 Point Count Hi 011 Point Count Lo 2Response FormatInput Byte Modbus Description Name Range Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 76 Slave Address MLAN Address7 Function Code 3 or 4 Top bit set on error8 Byte Count 49 Data Word 0 Hi Steady State Rate10 Data Word 0 Lo Steady State Rate11 Data Word 1 Hi Steady State Rate12 Data Word 1 Lo Steady State Rate0 to4294967295Grams (or tenths of grams)per hour32