Get Cycle Weight and TimeDescription: Returns the size of the last batch/cycle and the duration of time betweenthe last two cycles.Command FormatOutput Byte Modbus Description Name Range MLAN Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 66 Slave Address MLAN Address7 Function Code 3 or 48 Register Hi Command Code 50Get Cycle Weight and TimeCommand9 Register Lo 010 Point Count Hi 011 Point Count Lo 3Response FormatInput Byte Modbus Description Name Range Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 96 Slave Address MLAN Address7 Function Code 3 or 4 Top bit set on error8 Byte Count 69 Data Word 0 Hi Cycle Weight10 Data Word 0 Lo Cycle Weight 0 to 6553511 Data Word 1 Hi Cycle Time12 Data Word 1 Lo Cycle Time13 Data Word 2 Hi Cycle Time0 to14 Data Word 2 Lo Cycle Time 4294967295Grams (or tenths of grams) inlast cycleNumber of interrupts duringthe last cycle (244/sec)20