Set Steady State RateDescription: Sets throughput rate. Note however that the blender will continue to resetthe rate accordingly to how much material is being consumed. This is useful ifyou know that the rate just changed, such as in extrusion control, and you don'twant to wait until the blender figures it out.Command FormatOutput Byte Modbus Description Name Range MLAN Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 156 Slave Address MLAN Address7 Function Code 168 Register Hi Command Code 65Set Steady State RateCommand9 Register Lo 010 Register Count Hi 011 Register Count Lo 412 Data Byte Count 813 Data Word 0 Hi Steady State Rate14 Data Word 0 Lo Steady State Rate15 Data Word 1 Hi Steady State Rate16 Data Word 1 Lo Steady State Rate17 Data Word 2 Hi Steady State Rate18 Data Word 2 Lo Steady State Rate19 Data Word 3 Hi Steady State Rate20 Data Word 3 Lo Steady State RateResponse Format0 to4294967295Grams (or tenths of grams)per hourInput Byte Modbus Description Name Range Description0 Transaction ID 01 Transaction ID 02 Protocol ID 03 Protocol ID 04 Total Data Length 05 Total Data Length 26 Slave Address MLAN Address7 Function Code 16 Top bit set on error54