Vital Subsystem4.10.1. SpecificationsTable 4–23. FSVT Board SpecificationsDescription59473-894-01 894-02Maximum number of Boards per <strong>VPI</strong> <strong>II</strong> System 2Board slots required 1Number of Discrete Timers per board 8Used for Vital Timers Number 1 through 8 9 through 16Minimum Run Time (minutes/seconds) 0:00Maximum Run Time (minutes/seconds) 59:59Assign to I/O Bus With Signature HeaderDrawing No. (ID letter)Jumper TB4 Timer Settings (min/max units seconds)Jumper TB3 Timer Settings (min/max tens seconds)Jumper TB2 Timer Settings (min/max units minutes)Jumper TB1 Timer Settings (min/max tens minutes)Time Setting Method59473-871-01 (A)00/09 seconds0/50 seconds00/09 minutes0/50 minutesJumper Selection4.10.2. AssembliesTable 4–24. FSVT Board AssembliesDescriptionPart NumberFSVT Board Assembly, 8 timers, for timers one through eight 59473-894-01FSVT Board Assembly, 8 timers, for timers nine through sixteen 59473-894-02P2511G, Rev. Jan/06 4–30 ALSTOM Signaling Inc.