WARNINGBeware of V-belts and belt driven componentsas the unit may start automatically.Before servicing unit, make sure theSTART/RUN-OFF switch is in the OFF positionor the unit is in Maintenance mode.Also disconnect the negative battery cable.WARNINGUNITS EQUIPPED WITH STAR-TRAK TWOWAY COMMUNICATION CAPABILITIES MAYHAVE THE ABILITY TO BE STARTED ORTURNED OFF REMOTELY REGARDLESS OFTHE SETTING OF THE START/RUN-OFFSWITCH.The unit is controlled locally and there canbe no two-way communication when theMode switch on the Remote MonitoringControl Box is in MAINTENANCE MODE.Therefore, when performing maintenanceon the unit, place the Mode switch in MAIN-TENANCE MODE. After the unit is serviced,return the Mode switch to REMOTE ON. (Referto Section 3.20.3 for more detailed informationon two-way communication.)WARNINGInspect battery cables for signs of wear, abrasionor damage at every Pre -Trip inspectionand replace if necessary. Also checkbattery cable routing to ensure that clampsare secure and that cables are not pinchedor chafing against any components.WARNINGUnder no circumstances should ether orany other starting aids be used to start engine.WARNINGDo Not Allow Configuration Jumper WireTo Touch Any Ground.WARNINGThe +5.0 VDC (terminal B) is common betweenthe Compressor Discharge PressureTransducer, the Compressor Suction PressureTransducer, and the RPM sensor. Ifthis circuit is shorted to ground (due to oneof the mentioned components being defective,or a worn wire) the MessageCenter willshow:SSuction Pressure: -14.7 PSIG (-1 Bar)SDischarge Pressure: 0 PSIG/BarSEngine RPM: 0.WARNINGKeep hands and arms away from unit whenoperating <strong>with</strong>out belt guard in place. Neverrelease a unit for service <strong>with</strong>out the beltguard securely tightened in placeWARNINGDo not start unit <strong>with</strong>out installing the evaporatorpanels as unit damage or body harmmay result.WARNINGDo not use a nitrogen cylinder <strong>with</strong>out apressure regulator. Cylinder pressure isapproximately 2350 psig (159.9 bar). Do notuse oxygen in or near a refrigerant systemas an explosion may occur. (SeeFigure 9 -26)WARNINGThe Compressor Discharge PressureTransducer does not have a Schrader valvein the connecting fitting. Any dischargepressure remaining in the compressor willbe released when removing the CDP.WARNINGCarrier Transicold does not recommend allowingthe compressor to pull less than 0PSIG/Bar at any time.62-106831--2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!