CAUTIONOnly a refrigerant drum containing R404ashould be connected to units covered bythis manual in order to pressurize the system.Any other gas or vapor will contaminatethe system, which will require additionalpurging and evacuation of the highside (discharge) of the system.CAUTIONDo not vapor charge R404A systems. Onlyliquid charging through the receiver outlet(King) valve is acceptable.CAUTIONDo not over tighten or damage the SV2 orSV4 enclosing tube assembly. Torque to17-ft pounds (2.4 Mkg). Also make sure allparts are placed on the enclosing tube inproper sequence to avoid premature coilburnout.CAUTIONWhen adding oil to the compressor, extremecare must be taken to ensure the hoseis immersed in the oil at all times. Otherwiseair and moisture will be drawn into the compressor.CAUTIONWhen removing the compressor cylinderhead leave two cylinder head bolts loose<strong>with</strong> threads engaged in the crankcase untilcylinder head is completely loosened toprevent any residual crankcase pressure.62-106831--4