12.07.2015 Views

Concentrated Solar Power, Getting to the heart of energy - LEONI

Concentrated Solar Power, Getting to the heart of energy - LEONI

Concentrated Solar Power, Getting to the heart of energy - LEONI

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

24 ICON Instrumentation Cableswww.leoni-communication-infrastructure.comInstrumentation CableRE-2X(St)HSWAH, Single & Multi-Pair, Collective Screen, 300 V, EN 50288-7AdvantagesHalogen freeFlame retardantUV resistantOil resistantMechanical protection via steel round wireApplicationFor transmission <strong>of</strong> analogue and digital signals in instrumentand control systems; where people are potentially endangeredin case <strong>of</strong> fire. Not allowed for direct connection <strong>to</strong> lowimpendance source. Recommended fpr indoor and outdoorinstallation in dry and wet locations. For direct burial.ConstructionConduc<strong>to</strong>r: plain annealed copper wire, stranded,size: 1 mm²Insulation: cross-linked polyethylene XLPEColour code: black / white, continuously numbered on whitecore (1, 2, …) for multielement cableWrapping: at least 1 layer <strong>of</strong> plastic tapeCollective screen: 24 µm aluminium / PETP tape over tinnedcopper drain wire, 0.5 mm²Inner sheath: low smoke zero halogen flame retardantcompound LSZH, blackArmour: galvanised round steel wiresOu<strong>the</strong>r sheath: low smoke zero halogen flame retardantcompound LSZH, blackTechnical dataFlame propagation:Test on single cable IEC 60332-1-2Test on bunched cables IEC 60332-3-24 (Cat.C)Smoke density: IEC 61034-2 (L.T. > 60 %)Limiting Oxygen Index (LOI): ASTM D 2863 (min. 30 %)Flammability temperature (FT): ISO 4589-3 ann. A(min. + 250 °C)Amount <strong>of</strong> halogen acid gas: IEC 60754-1 (0 %)Degree <strong>of</strong> acidity <strong>of</strong> gases: IEC 60754-2 (pH > 4.3,C < 10µS/mm)Oil resistance: ICEA S-73-532*Sunlight resistance: UL 1581 Section 1200Temperature range:(during operation) – 30 °C up <strong>to</strong> + 90 °C(during installation) – 5 °C up <strong>to</strong> + 50 °CMinimum bending radius: 10 × cable diameter*(Test temperature: + 60 °C; test duration 4 h. Tensile strength and elongation atbreak: at least 60 % <strong>of</strong> <strong>the</strong> values before aging)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!