www.leoni-communication-infrastructure.comCircuit integrityunder fireTechnical Information95The circuit integrity indicates, how long a free cable retains itsisolation in a fire without causing a short-circuit. According <strong>to</strong> itsinternational standard, a cable is laid horizontally over a burnerfor three hours. The temperature is set at 800 °C. The circuitintegrity is designated with FE (e.g. FE180 = circuit integrity <strong>of</strong>180 min): BETAflam® FE180 / E30Test proceduresThe sample is fastened at definited distances above <strong>the</strong> burner.The conduc<strong>to</strong>r is connected <strong>to</strong> a power source at nominal voltagevia an 2 A fuse. The test is considered <strong>to</strong> be passed, if during<strong>the</strong> test no short circuit or circuit interruption occurs.Test standardsIEC 60331-11 und -21IEC 60331 Tests on electric cables and fire conditions – insulationmaintenanceIEC 60331-1 Fire with shock at a flame temperature <strong>of</strong> at least830 °C for cables and insulated conduc<strong>to</strong>rs withnominal voltages up <strong>to</strong> and including 0,6/1 kVand an external diameter <strong>of</strong> more than 20 mmIEC 60331-2 Fire with shock at a flame temperature <strong>of</strong> at least830 °C for cables and insulated conduc<strong>to</strong>rs withnominal voltages up <strong>to</strong> and including 0,6/1 kVand an external diameter equal <strong>to</strong> or smaller than20 mmIEC 60331-3 Fire with shock at a flame temperature <strong>of</strong> at least830 °C for cables and insulated conduc<strong>to</strong>rs withnominal voltages up <strong>to</strong> and including 0,6/1 kVtested in a metal tubeIEC 60331-11 Apparatus Fire alone at temperature <strong>of</strong>at least 750 °CIEC 60331-21 Procedures and requirements – Cables <strong>of</strong> ratedvoltage up <strong>to</strong> and including 0.6/1 kVIEC 60331-22 Procedures and requirements – Cables <strong>of</strong> ratedvoltage greater than 1 kV (under consideration)IEC 60331-23 Proc. and requirements – Electric data cablesIEC 60331-25 Proc. and requirements – Optical fiber cables4570 ± 10RSTN, PE1200Cable70 ± 10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!