12.07.2015 Views

Concentrated Solar Power, Getting to the heart of energy - LEONI

Concentrated Solar Power, Getting to the heart of energy - LEONI

Concentrated Solar Power, Getting to the heart of energy - LEONI

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

72 Connection and power cableswww.leoni-communication-infrastructure.comShielded connection cableBETAdrive C-flex 600 / 1000 V with symmetrical conduc<strong>to</strong>r layout, non-flame propagatingAdvantagesEMC optimised braided shieldingMulticore and flexibleSym. conduc<strong>to</strong>r layout, esp. earth conduc<strong>to</strong>r <strong>to</strong> phase conduc<strong>to</strong>rVery good oil and chemical resistanceHigh fire performanceHalogen free, UV and wea<strong>the</strong>r resistantApplicationFixed/flexible applications for average mechanical stress used indry, humid and wet rooms. UV an wea<strong>the</strong>r resistant. This cable isespecially designed and electrically optimised for power supplybetween frequency converters and low-voltage electric mo<strong>to</strong>rs.ConstructionConduc<strong>to</strong>r: Bare fine CU strands acc. <strong>to</strong> VDE 0295/IEC 60228, class 5Insulation: Polyolefine copolymer,colour <strong>of</strong> conduc<strong>to</strong>rs acc. <strong>to</strong> HD 308 S2Earth conduc<strong>to</strong>r: Bare fine CU strands, insulation , 3 conduc<strong>to</strong>rsTape: Plastic tape around strandingShielding: Alu tape,above it tinned fine copper braid, 85 % coveringDual layer sheath: Inside: Polyolefine copoylmer | Outside: TPEColour <strong>of</strong> sheath: ● blackStandard specifications / Material propertiesHalogen free: IEC 60754-1, EN 50267-2-1No corrosive gases: IEC 60754-2, EN 50267-2-2No <strong>to</strong>xic gases: NF X 70-100Resistance <strong>to</strong> oil: EN 60811-2-1 (24 h/70 °C),SEV TP 20 B/3 C (72 h/70 °C)Approval Gost R: Certificate no. POCC CH.AB28.B06470Fire perfomancesLow smoke density: IEC 61034, EN 50268-2Flame retardant: EN/IEC 60332-1-2Non-flame propagating: IEC 60332-3, EN 50266-2Low fire load: DIN 51900Technical dataNomimal voltage: U₀/U600 / 500 VTesting voltage: conduc<strong>to</strong>r/conduc<strong>to</strong>r 3500 Vconduc<strong>to</strong>r/shielding2500 VTemp. range: continuous duty + 90 °Cemergency service (< 8 h/day; 30 mm 15 × Cable- 10 × Cable-

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!