12.07.2015 Views

Concentrated Solar Power, Getting to the heart of energy - LEONI

Concentrated Solar Power, Getting to the heart of energy - LEONI

Concentrated Solar Power, Getting to the heart of energy - LEONI

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

64 Connection and power cableswww.leoni-communication-infrastructure.comConnection and power cable temperature resistantBETAflam® 145 flex 450 / 750 V (600 / 1000 V)AdvantagesVery high resistance <strong>to</strong> temperature,operation temperature up <strong>to</strong> + 145 °CResistance <strong>to</strong> cold up <strong>to</strong> – 55 °CBest fire performance, halogen freeGood resistance <strong>to</strong> aggressive mediaElectron-beam cross-linkedApplicationFixed and flexible application in dry, humid and wet rooms.Good resistance <strong>to</strong> wea<strong>the</strong>ring, ozone, UV-rays and oil, suitablefor outdoor use. Typical applications are for example for <strong>the</strong> connection<strong>of</strong> lamps, heating appliances, electric machines (insulationclass B), panels, switch cabinets and switchboards in apparatus,mechanical and plant engineering.ConstructionConduc<strong>to</strong>r: Tinned fine CU strandsacc. <strong>to</strong> VDE 0295/IEC 60228, class 5Insulation: Polyolefine copolymer electron-beam cross-linkedColour <strong>of</strong> conduc<strong>to</strong>rs:≤ 5: cores acc. <strong>to</strong> HD 308 S2 (colour code see page 75)≥ 6: cores ● with numbers printed in white or● with numbers printed in white andOuter sheath: Polyolefine copolymer electron-beam cross-linkedColour <strong>of</strong> sheath: ● blackTechnical dataNomimal voltage: U₀/U ≤ 1 mm 2 300 / 500 VU₀/U ≥ 1.5 mm 2for fixed and protected installation U₀/U ≥ 1.5 mm 2Testing voltage:450 / 750 V600 / 1000 V3500 VMax. conduc<strong>to</strong>r temp.: fixed installation + 145 °Coccasionally moved + 120 °Cshort circuit + 280 °CMin. ambient temp.: fixed installation – 55 °Coccasionally moved – 35 °CMin. bending radius: fixed installation > 4 × outer occasionally moved >8 × outer Standard specifications / Material propertiesHalogen free: IEC 60754-1, EN 50267-2-1No corrosive gases: IEC 60754-2, EN 50267-2-2No <strong>to</strong>xic gases: NF X 70-100Low smoke density: IEC 61034, EN 50268-2Flame retardant: EN/IEC 60332-1-2Non-flame propagating: IEC 60332-3, EN 50266-2, NF C 32-070Low fire load: DIN 51900Ship and <strong>of</strong>fshore approvalsGermanischer Lloyd (GL) certificate no. 96627-94HHLloyd’s Register (LR) certificate no. 03/20057BUREAU VERITAS (BV) certificate no. 13348/B1 BVDET Norske Veritas (DNV) certificate no. E-8948/8950CHINA CLASSIFICATION SOCIETY (CCS)certificate no. HB11 W00001T_02Gost R certificate no. POCC CH.AB28.B06470SpecialitiesDNV approval BETAflam® 145 flex FE180 availableUL/CSA approval in processSpecial types upon request

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!