www.leoni-communication-infrastructure.comICON Instrumentation Cables29Electrical Propertiesaften at 20 °CConduc<strong>to</strong>r resistance: max. 18,5 Ω/kmInsulation resistance: min. 5000 MΩ × kmMutual capacitance: max. 150 nF/kmInductance: max. 1 mH/kmCapacitance unbalance: max. 500 pF/500 mL/R ratio: max. 25 µH/ΩTest voltage U rms(core : core):1500 VTest voltage U rms(core : screen):1500 VOperating voltage:300 VGeometrical dataNo. <strong>of</strong> elements RT <strong>of</strong> insulation RT <strong>of</strong> inner sheathDia. over innersheath 1Dia. <strong>of</strong> armourwireRT <strong>of</strong> outer sheath Outer dia. Weightnom. nom. approx. nom. nom. approx. approx.1 mm²/7 (mm) (mm) (mm) (mm) (mm) (mm) (kg/km)1 0,40 0.9 6.3 0.9 1.3 10.7 2212 0.40 0.9 9.2 0.9 1.4 13.8 3334 0.40 1.0 10.9 0.9 1.4 15.5 4256 0.40 1.0 13.0 0.9 1.4 17.6 53810 0.40 1.3 16.3 1.25 1.6 22.0 863RT = Radial ThicknessRE = Instrumentation2X = XLPE Insulation(St) = Collective ScreenH = LSZH inner and outer sheathSWA = Steel round wire armouringHX = cross-linked LSZH Outer sheath